This accessory is the Intermatic K121 receptacle only. The K121 is for use with Intermatic K1200, K4500 and LC4500 series locking type photocells. Each Intermatic K121 comes with 8" black, white and red leads. This receptacle only operates on 105 to 480 volt circuits. The physical dimensions of the Intermatic K121 is approximately 2 1/2” wide by 1 1/2” long. They are NOT UL or CSA certified. Click here to see the Intermatic Photo Controls Instruction Sheet.
Tips To Optimize Photocell Performance
Do not face the photocell into the midday sun. If the photo control is installed on the south side of a building, face the photocell east or west or point the photo control down toward the ground. The best direction to face the photo control is north.
Do not face the photocell where it can see artificial light. Light from windows, signs, street lights, etc., will cause the photo control not to switch on. The photo control should not be positioned so that it sees the light it is controlling (or reflected light - like off of your white siding or white painted soffit overhang). These conditions will cause the light to cycle on and off.
Do not install the photo control with wires up unless there is NO POSSIBILITY of water
entering the photo control around the wires. The photo control must be installed in an approved weatherproof box. Do not attempt to caulk around the wires. Installing a Photocell below the box is WRONG! Photocells installed on top of the Box is RIGHT! Any Photo Control installed by the side of the weatherproof box is: ACCEPTABLE!
When you are testing the photocell, be sure to turn on the power (load will come on)
and wait up to 5 minutes for the photocell to switch load off. For further testing cover the photo control completely with black tape or another dark material to simulate night conditions. If you can’t cover the control with tape, try covering the photo control with the shipping carton to simulate night conditions.